¬ť∂Ļ…Ámadou

Őż stay¬∑safe¬ģ CAPD System

Continuous ambulatory peritoneal dialysis (CAPD) is a simple, safe, and effective peritoneal dialysis (PD) technique, especially for patients who have been identified as low or low-average transporters.1

Learn More About stay‚ÄĘsafe CAPD

To learn more about stay‚ÄĘsafe, please fill out the form below.

Consider CAPD for Incident and Incremental End Stage Renal Disease (ESRD) Patients

  • 85 percent of incident end stage renal disease (ESRD) patients start dialysis with a GFR >5mL/min/1.73m22
  • The CAPD modality can provide a gentler onboarding process

Potential Benefits of CAPD for ESRD PatientsŐż

  • Better preservation of residual kidney function3
  • Greater ultrafiltration and sodium removal for appropriate patients4
  • Increased phosphorus clearance5
  • Improved sleep quality6

stay‚ÄĘsafe - An Innovative Design to Support CAPD Patients

stay‚ÄĘsafe‚Äôs simple and smart product design supports patients during a CAPD exchange and is designed to reduce patient dropouts due to technique failure, infections, burnout, or other common reasons. The goal is to make the therapy more intuitive and help patients in reducing procedural steps to reduce the overall therapy burden in the long run.

A. Every PD exchange starts with ‚ÄúDrain‚ÄĚ by default.

B. The stay‚ÄĘsafe DISC with the blue dial guides the patients in only 4 steps: Drain, Flush, Fill, and Close. The stay‚ÄĘsafe DISC eliminates the need to clamp and unclamp lines. It may be easier to train patients on stay¬∑safe CAPD.7

C. The stay‚ÄĘsafe PIN automatically closes the catheter extension set before disconnection.

Three Unique stay‚ÄĘsafe CAPD Features

The stay‚ÄĘsafe CAPD system‚Äôs is designed to help patients perform their daily self-care CAPD treatment in a safe and convenient way. The stay‚ÄĘsafe CAPD system‚Äôs unique featuresŐżincluding the stay‚ÄĘsafe DISC, stay‚ÄĘsafe PIN, and stay‚ÄĘsafe Organizer work together to promote ease of use.

The stay‚ÄĘsafe Organizer

The stay‚ÄĘsafe Organizer is designed to bring all parts of the stay‚ÄĘsafe CAPD system together and includes built-in locations for the stay‚ÄĘsafe catheter extension set and stay‚ÄĘsafe cap. This all-in-one Organizer simplifies the patient‚Äôs role in the CAPD exchange procedure.

The stay‚ÄĘsafe DISC

The central part of the stay‚ÄĘsafe CAPD system is theŐżDISC with its distinctive blue dial. By simply turning the dial, the patient performs all the essential stepsŐżof the CAPD procedure: drain, flush, fill, and close.

The stay‚ÄĘsafe PIN Technology

When turning the dial to the fourth step (PIN/Close),Őża PIN is inserted into the catheter extension set before disconnecting from the system. The number of systems openings is reduced by 50% which may reduce the potential risk of contamination.

stay‚ÄĘsafe CAPD DesignŐż‚ÄĒ Easy to Learn, Easy to Use

Intuitive operation and simple patient instructions designed to promote successful treatment

Step 1: Drain

ŐżTo begin, open the clamp on the catheter extension set. The dial is already set to Position 1 (Drain).

Step 3: Fill

After the Flush step, turn the dial to Position 3 to Fill theŐżperitoneal cavity with DELFLEX¬ģŐżDextrose Peritoneal Dialysis Solution. The stay‚ÄĘsafe DISC allows control of fluid flow duringŐżthe Fill.

Step 2: Flush

Once the Drain step is completed, turn the dial to Position 2Őżto Flush the tubing.

Step 4: PIN/Close

When the Fill step is completed, turn the dial to the finalŐżPosition 4 to PIN/Close.

stay‚ÄĘsafe PIN Technology

Catheter connection technique is known to be a factor contributing to peritonitis rates.8ŐżWith the stay‚ÄĘsafe system‚Äôs patented PIN technology, the potential for accidental contamination and subsequent infection may be reduced.

The stay‚ÄĘsafe PIN seals the fluid pathway prior to catheter extension set disconnection during both CAPD and APD. With only one system opening per treatment, the stay‚ÄĘsafe CAPD system has half the openings of conventional CAPD systems, which may reduce the potential risk of touch contamination

.

25 Years of stay‚ÄĘsafe

Since 1996, stay‚ÄĘsafe has provided trusted CAPD technology to peritoneal dialysis patients around the world technology to dialysis patients around the world and has been in the U.S.Őżmarket since 2004.

The stay‚ÄĘsafe PIN technology is used in APD with the Liberty¬ģSelect cycler.ŐżToday, over 20,000 PD patients in the U.S. benefit from the advantages of the stay‚ÄĘsafe PIN technology to perform CAPD and APD with ease.

Őż

TRUSTED FOR MORE THAN 25 YEARS

Őż

References:

  1. Blake PG & Daugirdas JT, Physiology of Peritoneal Dialysis, Handbook of Dialysis 5th edition, pp. 392 -407.
  2. United States Renal Data System. 2020 USRDS Annual Data Report: Epidemiology of kidney disease in the United States. National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD, 2020.
  3. Nongnuch, A., Assanatham, M., Panorchan, K., Davenport, A., Strategies for preserving residual renal function in peritoneal dialysis patients, Clinical Kidney Journal, Volume 8, Issue 2, April 2015, Pages 202‚Äď211, https://doi.org/10.1093/ckj/sfu140.
  4. Maharjan SRS, Davenport A. Comparison of sodium removal in peritoneal dialysis patients treated by continuous ambulatory and automated peritoneal dialysis. J Nephrol. 2019 Dec;32(6):1011-1019.
  5. Courivard & Davenport (2015) Phosphate removal in PD; Peritoneal Dialysis International, Vol. 36, pp.85‚Äď93.
  6. Roumeliotis et al (2020), APD or CAPD: one glove does not fit all. Int. Urology and Nephrology, https://doi.org/10.1007/s11255-020-02678-6.
  7. Lambert, MC, Lage, C, Kirchgessner, J., stay‚ÄĘsafe¬ģ. A new PVC free system. EDTNA|ERCA JOURNAL 1999 XXV 3.
  8. Port, F.K., P.J. Held, K.D. Knolph, M.N. Turenne, R.A. Wolfe. ‚ÄúRisk of Peritonitis and Technique Failure by CAPD Connection Technique: A National Study.‚ÄĚ Kidney International 42 (1992): 967-974.

Indications for Use:ŐżDELFLEX is indicated in the treatment of chronic kidney failure in patients being maintained on peritoneal dialysis.

DELFLEX is available by prescription only.

IMPORTANT SAFETY INFORMATION

  • Intended for intraperitoneal administration only
  • Not for intravenous or intra-arterial administration
  • Use aseptic technique throughout the procedure
  • Monitor routinely for electrolyte, fluid, and nutrition imbalances
  • Monitor for signs of peritonitis or overfill
  • Inspect the drained fluid for fibrin or cloudiness
  • Ensure that there is no leakage around the catheter
  • Solution-related adverse reactions may include peritonitis, catheter site infection, electrolyte and fluid imbalances, hypovolemia, hypervolemia, hypertension, disequilibrium syndrome, muscle cramping, abdominal pain, abdominal distension, and abdominal discomfort

To report SUSPECTED ADVERSE REACTIONS, contact ¬ť∂Ļ…Ámadou Medical Care North America at 800-323-5188. You are encouraged to report negative side effects of prescription drugs to the FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. Visit MedWatch or call 1-800-FDA-1088.

¬ť∂Ļ…Ámadou CAPD stay‚ÄĘsafe¬ģŐżDisposable Administration Sets with stay‚ÄĘsafe¬ģŐżConnector:

The ¬ť∂Ļ…Ámadou CAPD stay‚ÄĘsafe¬ģŐżDisposable Administration Sets with stay‚ÄĘsafe¬ģŐżConnector is indicated for use in end-stage acute and chronic renal disease.
Liberty¬ģŐżSelect

stay‚ÄĘsafe Catheter extension set:

The stay‚ÄĘsafe catheter extension set with Luer-Lock is indicated for use in patients with acute and chronic end-stage renal disease undergoing peritoneal dialysis (PD) in a healthcare facility or at home. The stay‚ÄĘsafe catheter extension set with Luer-Lock is used to connect a PD catheter with a Luer-Lock catheter adapter to PD systems that use stay‚ÄĘsafe PIN technology.

stay‚ÄĘsafe Cap:

The ¬ť∂Ļ…Ámadou sterile stay‚ÄĘsafe¬ģŐżCap is intended to be used for closure of the stay safe stay‚ÄĘsafe peritoneal dialysis connectology system.

Liberty Select Cycler:

Indications for Use:ŐżThe ¬ť∂Ļ…Ámadou Liberty Select Cycler is indicated for acute and chronic peritoneal dialysis.

Caution:ŐżFederal (US) law restricts this device to sale by or on the order of a physician.

Note:ŐżRead the Instructions for Use for safe and proper use of this device. For a complete description of hazards, contraindications, side effects, and precautions, see full package labeling at www.fmcna.com.

¬©2009, 2018-2023 ¬ť∂Ļ…Ámadou Medical Care. All Rights Reserved. ¬ť∂Ļ…Ámadou Medical Care, the triangle logo, Liberty, stay¬∑safe, and DELFLEX are trademarks of ¬ť∂Ļ…Ámadou Medical Care Holdings Inc. or its affiliated companies. All other trademarks are the property of their respective owners. P/N 100969-01 Rev F 06/2023

Őż